Lighting columns - Part 4: Requirements for reinforced and prestressed concrete lighting columns
Summary
This European Standard specifies requirements for reinforced and prestressed concrete lighting columns. It applies to columns not exceeding 20 m height for post top lanterns and columns with brackets not exceeding 18 m height for side entry lanterns.
This European Standard specifies:
a) performance related to the essential requirement of resistance to horizontal (wind) loads, measured in accordance with EN 40-3;
b) performance under vehicle impact (passive safety) in support of the Essential Requirement No. 4 Safety in use, measured in accordance with the corresponding test methods included in this document or available in separate European Standards.
This European Standard specifies:
a) performance related to the essential requirement of resistance to horizontal (wind) loads, measured in accordance with EN 40-3;
b) performance under vehicle impact (passive safety) in support of the Essential Requirement No. 4 Safety in use, measured in accordance with the corresponding test methods included in this document or available in separate European Standards.