Superseded
Standard
Historical
CSA Z23500-2:20 (R2024)
Preparation and quality management of fluids for haemodialysis and related therapies — Part 2: Water treatment equipment for haemodialysis applications and related therapies (Adopted ISO 23500-2:2019, first edition, 2019-02, with Canadian deviations)
Summary
N/A
CSA Preface This is the first edition of CSA Z23500-2, Preparation and quality management of fluids for haemodialysis and related therapies — Part 2: Water treatment equipment for haemodialysis applications and related therapies , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 23500-2 (first edition, 2019-02). It replaces CAN/CSA-ISO 26722:16 (adopted ISO 26722:2014), Water treatment equipment for haemodialysis applications and related therapies. For brevity, this Standard will be referred to as “CSA Z23500-2” throughout. This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Quality Management for Kidney Dialysis, under the jurisdiction of the CSA Technical Committee on Kidney Dialysis and the CSA Strategic Steering Committee on Health and Well-being, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This document is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapies. 1.2 Inclusions This document covers devices used to treat potable water intended for use in the delivery of haemodialysis and related therapies, including water used for: a) the preparation of concentrates from powder or other highly concentrated media at a dialysis facility; b) the preparation of dialysis fluid, including dialysis fluid that can be used for the preparation of substitution fluid; c) the reprocessing of dialysers intended for single use where permitted for multiple uses d) the reprocessing of dialysers not specifically marked as intended for single use. This document includes all devices, piping and fittings between the point at which potable water is delivered to the water treatment system, and the point of use of the dialysis water. Examples of the devices are water purification devices, online water quality monitors (such as conductivity monitors), and piping systems for the distribution of dialysis water. 1.3 Exclusions This document excludes dialysis fluid supply systems that proportion water and concentrates to produce dialysis fluid, sorbent dialysis fluid regeneration systems that regenerate and recirculate small volumes of the dialysis fluid, dialysis concentrates, haemodiafiltration systems, haemofiltration systems, systems that process dialysers for multiple uses, and peritoneal dialysis systems. Some of these devices, such as dialysis fluid delivery systems and concentrates, are addressed in other documents such as ISO 23500-4 and ISO 23500-5, This document also excludes the on-going surveillance of the purity of water used for dialysis fluid, concentrate preparation, or dialyser reprocessing which is addressed in ISO 23500-1.
CSA Preface This is the first edition of CSA Z23500-2, Preparation and quality management of fluids for haemodialysis and related therapies — Part 2: Water treatment equipment for haemodialysis applications and related therapies , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 23500-2 (first edition, 2019-02). It replaces CAN/CSA-ISO 26722:16 (adopted ISO 26722:2014), Water treatment equipment for haemodialysis applications and related therapies. For brevity, this Standard will be referred to as “CSA Z23500-2” throughout. This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Quality Management for Kidney Dialysis, under the jurisdiction of the CSA Technical Committee on Kidney Dialysis and the CSA Strategic Steering Committee on Health and Well-being, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 General This document is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapies. 1.2 Inclusions This document covers devices used to treat potable water intended for use in the delivery of haemodialysis and related therapies, including water used for: a) the preparation of concentrates from powder or other highly concentrated media at a dialysis facility; b) the preparation of dialysis fluid, including dialysis fluid that can be used for the preparation of substitution fluid; c) the reprocessing of dialysers intended for single use where permitted for multiple uses d) the reprocessing of dialysers not specifically marked as intended for single use. This document includes all devices, piping and fittings between the point at which potable water is delivered to the water treatment system, and the point of use of the dialysis water. Examples of the devices are water purification devices, online water quality monitors (such as conductivity monitors), and piping systems for the distribution of dialysis water. 1.3 Exclusions This document excludes dialysis fluid supply systems that proportion water and concentrates to produce dialysis fluid, sorbent dialysis fluid regeneration systems that regenerate and recirculate small volumes of the dialysis fluid, dialysis concentrates, haemodiafiltration systems, haemofiltration systems, systems that process dialysers for multiple uses, and peritoneal dialysis systems. Some of these devices, such as dialysis fluid delivery systems and concentrates, are addressed in other documents such as ISO 23500-4 and ISO 23500-5, This document also excludes the on-going surveillance of the purity of water used for dialysis fluid, concentrate preparation, or dialyser reprocessing which is addressed in ISO 23500-1.
Technical characteristics
| Publisher | Canadian Standards Association (CSA) |
| Publication Date | 01/01/2020 |
| Confirmation Date | 01/01/2024 |
| Page Count | 56 |
| Themes | Health Care Technology |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
No products.
Previous versions
01/01/2020
Superseded
Historical
No products.