IEC 61249-2-47:2018
IEC 61249-2-47:2018 Materials for printed boards and other interconnecting structures - Part 2-47: Reinforced base materials clad and unclad - Non-halogenated epoxide non-woven/woven E-glass reinforced laminate sheets of thermal conductivity 2,0 W/(m•K) and defined flammability (vertical burning test), copper-clad for lead-free assembly
Summary
IEC 61249-2-47:2018 gives requirements for properties of non-halogenated epoxide non-woven reinforced core/woven E-glass reinforced surface laminate sheets of thermal conductivity and defined flammability (vertical burning test), copper-clad for lead-free assembly in thicknesses of 0,60 mm up to 1,70 mm. The flammability rating is achieved through the use of non-halogenated fire retardants reacted as part of the epoxide polymeric structure. The glass transition temperature is defined to be 105 °C minimum. Thermal conductivity is defined to be (2,0 ± 0,30) W/(m•K).
Technical characteristics
| Publisher | International Electrotechnical Commission (IEC) |
| Publication Date | 01/10/2018 |
| Edition | 1.0 |
| Page Count | 22 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |