IEEE P2748

IEEE P2748

IEEE Approved Draft Recommended Practice for Fault Diagnosis and Protection in Smart Distribution System

Disponibilidad: En stock

90,00 €

Detalles

New IEEE Standard - Active - Draft.
This recommended practice provides the fault diagnosis and protection schemes and application cases for smart distribution systems from AC 6 kV to 20 kV, covering security requirements, architectures, and configuration, as well as basic functions and technical indexes of software systems and hardware terminals, and requirements of information exchange. Schemes provided in this document are adaptable to various grid operation modes, control patterns, equipment conditions, and reliability requirements of distribution systems. This recommended practice is mainly based on engineering practices in the voltage range of 6 kV-20 kV. The proposed FLISR schemes can also be used in the voltage range of 2.4 kV - 38 kV as specified in ANSI C84.1 after an evaluation of communication conditions and cost analysis. The fault types cover phase (three-phase and phase-to-phase) faults, ground (three-phase-to-ground, two-phase-to-ground and single-phase-to-ground) faults and conductor-broken faults.Changes and needs brought by the connection of distributed generators are considered. And schemes empowered by information and communication technologies are also introduced.

This recommended practice focuses on the configurations and strategies of fault diagnosis and protection corresponding to different grid operation modes, control patterns, equipment conditions and reliability requirements in smart distribution network. With the development of information and communication technology (ICT), there is diverse and abundant data in monitoring and control systems for distribution network. And due to the connection of Distributed Generations and electric vehicles, the distribution network becomes more diversified and complex. Considering different distribution network conditions and requirements, this recommended practice provides valuable practices relevant to the fault diagnosis and protection strategies including safety operation requirements, architecture of fault diagnosis and protection configuration, basic functions and technical indexes of software systems and hardware terminals, the realization modes of fault diagnosis and protection, relevant information exchange demand, etc. The fault types cover faults of line break, single-phase-to-ground and short circuit, etc. This recommended practice applies to distribution system from 6kV to 20kV.
In view of the fact that a single fault diagnosis and protection strategy cannot adapt to various configurations of smart distribution networks, an effective fault diagnosis and protection method should be able to adjust with changes of the monitoring and operating conditions, network topology and reliability requirement of smart distribution networks. Therefore, it is needed to propose different fault diagnosis and protection strategies according to different grids operation modes, control patterns, equipment conditions and reliability requirements in smart distribution networks.
This recommended practice provides valuable experience for planners and operators in the matter of fault diagnosis and protection configuration. It is intended to provide preferred strategies of fault handling according to different grids situation and users requirements.
The implementation of this recommended practice will help enhance safety and the normative operation for smart distribution networks.

Información adicional

Autor Institute of Electrical and Electronics Engineers (IEEE)
Comité Transmission and Distribution
Publicado por IEEE
Tipo de Documento Proyecto de norma
Edición
EAN ISBN 979-8-8557-0151-7
Número de páginas 78
Palabra clave IEEE P2748
Formulario de pedido