Code for Facilities, Technology and Inspection for Manufacturing of Cast Iron Gas Burners

39,00 €

Details

"1.1.1 This Code applies to the facilities, technology and inspection for manufacturing of cast iron gas burners burning liquefied petroleum gas or city gas (hereinafter referred to as 'cast iron burners') which come under the following (1) to (2) among the burners in conformity to the Enforcement Regulation of the Safety Control and Business of Liquefied Petroleum Gas Act (hereinafter referred to as 'Enforcement Regulation'), Table 3, No. 10 and Table 7, No.4-j:
(1) The total heat input rate is not over 232.6 kW (200,000 kcal/h), and
(2) The working gas pressure is not over 30 kPa.

1.1.2 The combustors excluded from the gas appliances subject to license in conformity to the Enforcement Regulation, Table 7, No.5-b are as follows:
(1) Gas torches used for welding and cutting,
(2) Dryer combustors used in casting sand dryers, printing ink dryers, concrete dryers, etc.,
(3) Furnace combustors for heat treatment furnaces or heating furnaces used as metal heat treatment furnaces, glass and ceramic furnaces, atmosphere gas furnaces, etc.,
(4) Melting furnace combustors used in metal melting, glass melting, etc.,
(5) Combustors attached to gas canisters of which internal volume is less than 100 mL, and
(6) Other combustors acknowledged by the Minister of Trade, Industry & Energy to be free from any problem in safety control."