"1.1.1 This Code applies to the facilities, technology and inspection for manufacturing of the liquefied petroleum gas oven ranges or city gas oven ranges (hereinafter referred to as 'gas oven ranges') which come under the following (1) to (4) among the combustors in conformity to the Enforcement Regulation of the Safety Control and Business of Liquefied Petroleum Gas Act (hereinafter referred to as 'Enforcement Regulation'), Table 3, No. 10 and Table 7, No.4-j :
(1) The total heat input rate is not over 22.6 kw (19,400 kcal/h).
(2) The heat input rate of one burner is not over 4.2 kw (3,600 kcal/h).
(3) The heat input rate of the oven part is not over 5.8 kW (5,000 kcal/h), and
(4) The working gas pressure is not over 3.3 kPa.

1.1.2 The combustors excluded from the gas appliances subject to license in conformity to the Enforcement Regulation, Table 7, No.5-b are as follows:
(1) Gas torches used for welding and cutting,
(2) Dryer combustors used in casting sand dryers, printing ink dryers, concrete dryers, etc.,
(3) Combustors for heat treatment furnaces or heating furnaces used as metal heat treatment furnaces, glass and ceramic furnaces, atmosphere gas producer furnaces, etc.,
(4) Melting furnace combustors used in metal melting, glass melting, etc.,
(5) Combustors attached to gas canisters of which internal volume is less than 100 mL, and
(6) Other combustors acknowledged by the Minister of Trade, Industry & Energy to be free from any problem in safety control."