VDI 2463 Blatt 2:2021-05

VDI 2463 Blatt 2:2021-05

Particulate matter measurement - Sampling of airborne particulate matter in ambient air - Active sampling with HVS (high volume sampler)

72,31 €

Détails

The particles dispersed in ambient air are collected on filters using a high volume sampler (HVS). The particle-laden filter is automatically replaced by a clean filter at the end of every sampling cycle and a new cycle is started. The mass of the particles collected on the filters is determined in each case from the difference in weight of the filter before and after sampling. The measurement result is reported as a concentration by mass. The standard specifies apparatus specific requirements with respect to an active sampling for the determination of particles and their constituents in ambient air with HVS. It defines basic requirements for the sampling apparatus and the sampling head as well as the permissible tolerances of the air volume of the HVS. For the determination of the particle mass concentration HVS are suitable for the operation in measurement stations and outdoors. The typical sampling period of an HVS is 24 hours for one filter. Depending on the measurement task also different sampling periods can be reasonable.

Informations supplémentaires

Auteur Verein Deutscher Ingenieure (VDI)
Edité par VDI
Type de document Norme
ICS 13.040.20 : Air ambiant
Nombre de pages 14
Remplace VDI 2463 Blatt 11 (1996-10), VDI 2463 Blatt 11 (2020-05)
Recueil VDI/DIN-Handbuch Reinhaltung der Luft Band 4
Mot-clé VDI 2463,2463