UL 1072:2006

UL 1072:2006

Medium-Voltage Power Cables

762,00 €

Détails

1.1 These requirements cover the shielded and nonshielded medium-voltage power cables that are described in Tables 1.1 (single-conductor) and 1.2 (multiple-conductor). Multiple-conductor cables may include one or more individually jacketed non-conductive optical-fiber members. These electrical and hybrid electrical and optical-fiber cables are for use (optical and electrical functions associated in the case of a hybrid cable) in accordance with Article 328 and other applicable parts of the National Electrical Code (NEC), ANSI/NFPA 70.



1.1 revised September 19, 2007



1.2 These cables have one or more stranded copper or aluminum conductors that are insulated with a solid, extruded dielectric. Cables that have a metal sheath or interlocked armor incorporate an effective grounding path. A grounding conductor is optional in other cables. Cables for direct burial are so marked and have an overall covering (see 1.4 for direct-burial cables that are not covered). Cables that are for use in cable trays generally are so marked (see 62.1 and 62.2). Cables that are sunlight-resistant generally are so marked (see 64.1 – 64.3). Cables that are marked “MV-90” or “MV-90 dry” have a maximum operating temperature of 90°C (194°F). Cables that are marked “MV-105” have a maximum operating temperature of 105°C (221°F) for use where design conditions require a maximum conductor temperature above 90°C (194°F). Cables that are marked “dry” have insulation for use only in dry locations. All other cables have insulation that is for use in both wet and dry locations. Multiple-conductor cables that include one or more optical-fiber members are surface marked to so indicate. Cables that are marked “oil resistant II” are for exposure to mineral oil at temperatures not in excess of 75°C (167°F). Cables that are marked “oil resistant I” are for exposure to mineral oil at temperatures not in excess of 60°C (140°F).



1.3 A multiple-conductor Type MV cable that has a smooth (other than lead) or corrugated metal sheath or that has interlocked metal armor may be marked for use also as Type MC cable.



1.4 This standard does not include requirements for cables with concentric neutral conductors. However, it is possible to have a single-conductor cable with a concentric neutral conductor manufactured in accordance with the requirements of other standards, that meets the requirements for jacketed single-conductor shielded cable in this standard.

Informations supplémentaires

Auteur Underwriters Laboratories (UL)
Edité par UL
Type de document Norme
Edition révision n° 4
ICS 29.060.20 : Câbles
Nombre de pages 131
Remplace UL 1072 (2001-12-28)
Poids (kg.) 0.32
Mot-clé UL 1072
ANSI Approved