ASTM C1392-20

ASTM C1392-20

Standard Guide for Evaluating Failure of Structural Sealant Glazing

Disponibilité: En stock.

51,00 €

Détails

1.1 ,This guide covers a screening approach to detect failure (adhesive or cohesive) of a structural sealant in a structural sealant-glazed window, curtain wall, or other similar system. Presently, only a silicone-sealant that is specifically formulated, tested, and marketed as a structural glazing sealant is allowed for structural sealant glazing.

1.2 ,The values stated in either acceptable metric units or in other units shall be regarded separately as the standard. The values stated in each system may not be exact equivalents, therefore, each system must be used independently of the other, without combining values in any way.

1.3 ,There are no ISO standards similar or equivalent to this ASTM standard.

1.4 ,This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 ,This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Significance and Use:

5.1 ,This guide suggests a simple means of evaluating the extent of any failure of a structural sealant in an installed structural sealant glazing system.

5.2 ,A qualified authority should specify the criteria described in Sections 8 and 9 and should interpret the results and judge their significance for the structural sealant glazing system.

5.3 ,The evaluation program measures deflection of loaded lites and does not measure directly any structural sealant failure. Consequently, the qualified authority interpreting the data should also evaluate the source of any increased deflection that is measured. Increased deflection may be due to structural sealant adhesive or cohesive failure, but may also be due to a decrease in sealant modulus, a change in sealant joint dimensions, or other nonfailure mechanisms. Selective destructive sampling of areas with increased deflections can assist in this evaluation.

Informations supplémentaires

Auteur American Society for Testing and Materials (ASTM International)
Comité C24.10 - Committee C24 on Building Seals and Sealants
Edité par ASTM
Type de document Norme
Thème ,Binders. Sealing materials
ICS 91.100.50 : Liants. matériaux d'étanchéité
Nombre de pages 6
Remplace ASTM C1392-00(2014)
Recueil ASTM Volume 04.07 - Multi-User - Single-Site Online
Historique ,,,
Mot-clé C1392

Vous pourriez aussi être intéressé(e) par le(s) produit(s) suivant(s)