Name | Support | Language | Availability | Edition date | Price | ||
---|---|---|---|---|---|---|---|
PDF |
English |
Active |
7/29/2022 |
€60.00 |
|
Details
This procedure establishes a recommended practice for performing a Low Speed Knee Slider test to the Hybrid III 50th Male Anthropomorphic Test Device (ATD or crash dummy). This test was created to satisfy the demand from industry to have a certification test which produces similar results to an actual low energy automotive impact test. An inherent problem exists with the current certification procedure because the normal (2.75 m/s) knee slider test has test corridors that do not represent typical displacements seen in these low energy impact tests. The normal test corridors specify a force requirement at 10 mm and at 18 mm, while the low speed test needs to have a peak displacement around 10 mm.
Additional Info
Author | Society of Automotive Engineers International (SAE) |
---|---|
Committee | Dummy Testing and Equipment Committee |
Published by | SAE |
Document type | Standard |
Confirmation date | 2022-07-29 |
ICS | 43.180 : Diagnostic, maintenance and test equipment
|
Number of pages | 5 |
Replace | SAE J 2876:2015-05-07 |
Document history | SAE J 2876:2015-05-07,SAE J 2876:2009-03-05 |
Keyword | SAE 2876,SAE J2876,SAE J2876,SAE J 2876 |